Single-layer fire resistant glass (BS476 Part22:1987、BS EN 1634-1:2008)
Thickness (mm) | Fireproof Performance | Fireproof Level | Weight(kg/㎡) | Fire Proof temperature℃ |
6 | E: Integrity | E30、 E60、 E90 | 15 | 》1000 |
8 | E: Integrity | E30、 E60、 E90 | 20 | 》1000 |
10 | E: Integrity | E30、 E60、 E90 | 25 | 》1000 |
12 | E: Integrity | E30、 E60、 E90 | 30 | 》1000 |
Double-layer fire resistant glass (BS476 Part22:1987、BS EN 1634-1:2008 、 BS EN 1364-1:1999)
Thickness (mm) | Fireproof Leve | Fireproof Performance | Weight(kg/㎡) | Mean furnace temperature℃ | Maximum temperature of unexposed side ℃ | |
Integrity | Insulation | |||||
19 | EI 30 | 30 | 30 | Approx.35 | 950 | ≤74.5 |
25 | EI 60 | 60 | 60 | Approx.45 | 980 | ≤60.5 |
42 | EI 120 | 120 | 120 | Approx.65 | 1100 | ≤68 |
FPOS Fire-resistant Glass(BS 476Part22:1987、BS EN1634-1:2008、BS EN1364:1:1999、AS 1530.4:2005)
Thickness (mm) | Fireproof Level | Fireproof Performance | Weight(kg/㎡) | Mean furnace temperature℃ | Maximum temperature of unexposed side ℃ | |
Integrity | Insulation | |||||
10 | EW 120 | 135 | 16 | Approx.21 | 1100 | 15kw/m2 |
21 | EW 120 | 122 | 30 | Approx.47.5 | 1100 | 15kw/m2 |
25 | EI 60 | 68 | 68 | Approx.52.5 | 1100 | ≤180 |
41 | EI 120 | 129 | 128 | Approx.81.5 | 1100 | ≤180 |
05-20
防(fang)火(huo)(huo)墻和防(fang)火(huo)(huo)隔墻有哪幾個方面的區別
(1)結(jie)構(gou)(gou)方法不(bu)同:①防火(huo)(huo)墻應(ying)直接設(she)置(zhi)(zhi)在建筑的根底或結(jie)構(gou)(gou)、梁(liang)等(deng)承(cheng)重結(jie)構(gou)(gou)上,結(jie)構(gou)(gou)、梁(liang)等(deng)承(cheng)重結(jie)構(gou)(gou)的耐火(huo)(huo)極(ji)限不(bu)該低于(yu)防火(huo)(huo)墻的耐火(huo)(huo)極(ji)限;而防火(huo)(huo)隔墻直接設(she)置(zhi)(zhi)在樓地面上既可。②防火(huo)(huo)墻的結(jie)構(gou)(gou)應(ying)能(neng)在防火(huo)(huo)墻任意(yi)一側的屋(wu)架、梁(liang)、樓板(ban)等(deng)遭到(dao)火(huo)(huo)災(zai)的影響而損壞時,不(bu)會導致防火(huo)(huo)墻倒塌;而防火(huo)(huo)隔墻卻(que)無此要(yao)求。 (2)防火(huo)(huo)和(he)耐火(huo)(huo)要(yao)求不(bu)同。①當(dang)高層廠房(fang)(倉(cang)庫)房(fang)頂承(cheng)重結(jie)構(gou)(gou)和(he)屋(wu)面板(ban)的耐火(huo)(huo)極(ji)限低于(yu)1.00h,其(qi)他建筑房(fang)頂承(cheng)重結(jie)構(gou)(gou)
05-20
各住宅安裝防(fang)火窗應(ying)需(xu)知的安全要求有哪(na)些
(一)一般(ban)民用修(xiu)建住所(suo) 1、住所(suo)修(xiu)建上下相鄰套房(fang)開口部位(wei)應(ying)設置高度(du)不(bu)(bu)低于(yu)0.8m的(de)(de)(de)窗檻墻或設置耐火(huo)極限(xian)不(bu)(bu)低于(yu)1.00h的(de)(de)(de)不(bu)(bu)燃性實(shi)體(ti)挑檐,其(qi)出(chu)(chu)挑寬度(du)不(bu)(bu)該(gai)小(xiao)于(yu)0.5m,長度(du)不(bu)(bu)該(gai)小(xiao)于(yu)開口寬度(du); 2、當(dang)修(xiu)建物(wu)的(de)(de)(de)外墻為難焚燒體(ti)時,防火(huo)墻應(ying)凸(tu)出(chu)(chu)墻的(de)(de)(de)外外表(biao)0.4m 以上,且在防火(huo)墻兩邊(bian)的(de)(de)(de)外墻應(ying)為寬度(du)不(bu)(bu)小(xiao)于(yu)2m 的(de)(de)(de)不(bu)(bu)焚燒體(ti),其(qi)耐火(huo)極限(xian)不(bu)(bu)該(gai)低于(yu)該(gai)外墻的(de)(de)(de)耐火(huo)極限(xian); 3、當(dang)修(xiu)建物(wu)的(de)(de)(de)外墻